EVAP Canister Purge Valve, 4-cyl
To remove
1. Undo the quick-release coupling on the purge hose connected to the evaporative emission canister, using tool No.83 95 261. Press the bracket
inwards.
2. Remove the purge valve from the bracket.
3. Carefully twist the purge valve and unplug the connector.
4. Remove the purge valve from the connecting hose.
To fit
Note: Spray the connector with Kontakt 61, part no.30 04 520, before plugging in.
1. Fit in reverse order.