saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Checking Control Module Ground|Page 8630 > < Checking Control Module Ground
Page 2
background image

Take a voltage reading.

4   : Control module, SPA connector 1
B - : Battery ground

The reading should be 2 V - 3 V

Checking the wiring harness

Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness.
Observe the multimeter, test lamp or diagnostic tool while doing this.

Is the function correct?

NO

-

See: Checking Bus Leads to Control Module 

YES -

Continue with Checking control module ground.

Take a voltage reading.

5   : Control module, SPA connector 1
B - : Battery ground

The reading should be 2 V - 3 V

Checking the wiring harness

Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness.

Checking Control Module Ground|Page 8630 > < Checking Control Module Ground