A poor ground connection will not cause a diagnostic trouble code to be generated. When connection to ground is restored after having been interrupted,
it corresponds to power turn-on and the control module again runs through the on-board diagnostics program. The airbag warning lamp will then lights
up for 3-4 seconds.

Connector

The control module's connector incorporates 5 short-circuiting jumpers which, when the connector is unplugged, short-circuit the leads in pairs to the
two electric detonators for the front airbags, the two electric detonators for the side airbags and also short-circuit the airbag warning lamp's wiring to
ground.