Internal circuitry 
Six Zener diodes are used to convert the alternating voltage generated by the stator windings into direct voltage.

The stator windings form three phases and are delta-connected.

An excitation diode is connected to each of the three stator windings.

The 6 rectifier diodes are bridge-connected. The diodes are pressed into a diode retainer.

Depending on the polarity, the diode retainer is either insulated from the casing or connected directly to it. The excitation winding is mounted on to the
rotor, which has claw-type poles. Alternate claws act as north poles, the remaining alternate claws as south poles.

The ends of the excitation winding are connected to slip rings over which the exciting current is fed.

Generator, Description of Operation 
When the ignition key is turned to ON or ST, +15 is supplied to MIU.
The voltage is fed from the ignition switch via the indicator lamp to terminal D+ on the generator and from there to the rotor's excitation winding and
then grounded via the regulator.