Rain Sensor: Description and Operation
Control Module Connection Test Values, Rain Sensor

Control Module Connection Test Values, Rain Sensor

Scope

This section contains the readings and instructions for measuring voltage levels on the SID unit.

Remember

-

Observe the conditions set for testing and use common sense when assessing the results.

-

First make sure that the control module is receiving power and that it is grounded.

-

Then check all the sensor inputs and signals from other systems.

-

Finally check the control module outputs. Remember that the test readings do not indicate whether the actuator is working.

-

If a test value is incorrect, consult the wiring diagram to trace which leads, connectors and components should be checked more thoroughly.

-

The specified test readings refer to those obtained with a calibrated Fluke 88/97.

-

The test readings show the signal's pulse ratio and pulse duration. A test instrument capable of giving pulse ratio and pulse duration readings
should be used. The sign indicates a positive trigger pulse, TRIG+.