The injectors are supplied with current from the main relay, while the Control module grounds them as follows:

-

Injector 1 is Controlled from pin 45.

-

Injector 2 is Controlled from pin 44.

-

Injector 3 is Controlled from pin 67.

-

Injector 4 is Controlled from pin 68.

The microprocessor Controls the transistor in the firing order so that injection is completed just as the inlet valve in the cylinder in question opens.

Diagnostics

-

If There is an open circuit or short circuit to ground or B+ on any of the injectors, diagnostic trouble code P1676 will be generated.

System Reaction To A Fault

-

Closed loop is blocked.