9-5 SE Sedan (9600) V6-3.0L Turbo (B308) (1999)
With the ignition switch in the ON position, current (+15 circuit) is supplied to pin 5 of the control module via fuse 28. The control module is designed
to operate on a power supply of between 9 and 16 V.
Grounding
The control module is connected to ground via pin 7 and the three retaining screws. No ground cables from other systems must be connected to the
retaining screws as this could cause malfunctioning of the SRS.