saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Condenser HVAC|Description and Operation|Page 5754 > < Condenser HVAC|Description and Operation|Page 5752
Page 2
background image

9

Unscrew the condenser, 2 bolts, and remove it by lowering it in front of the radiator.

10

Remove the receiver so that it can be transferred to the new condenser.

IMPORTANT
If the receiver has been open for more than a total of 15 minutes, it must be replace

11

Remove the pressure sensor for transferral.

To fit

1

Fit the receiver to the condenser.

2

Lubricate the O-ring and fit the pressure sensor to the condenser.

Tightening torque: 7-9 Nm (5.2-6.7 ft. lbs.)

3

Adjust the oil volume in the compressor.

4

Lift up the condenser in front of the radiator until it is located in the lower locating groove.

5

Screw the condenser to the upper mounting points, 2 bolts.

6

Remove the plugs and lubricate the O-rings on the A/C pipes.

Condenser HVAC|Description and Operation|Page 5754 > < Condenser HVAC|Description and Operation|Page 5752