IMPORTANT

Vacuum pumping should be done on simultaneously on both the high pressure and low pressure sides. A non- return valve on the compressor low
pressure side makes it impossible to vacuum pump from only one side.

1. Using a snap-on coupling, connect the blue low-pressure hose to the low-pressure side of the A/C system.
2. Using a snap-on coupling, connect the red high-pressure hose to the high-pressure side of the A/C system.
3. Open the valves on both snap-on couplings by screwing in the knobs.
4. Open the valves on the blue low-pressure hose and red high-pressure hose on the pressure gauge stand.
5. Open the blue valve ("Liquid") for liquid refrigerant on the Smart Cart container.
6. Check that the valve on the yellow hose on the pressure gauge stand middle outlet is closed.

7. Programme 30 minutes vacuum pumping by pressing "30" on the control panel in position "Vacuum minus".
8. Press "REV.PROG."
9. Press "0.87" to indicate the amount of refrigerant (in kilograms) to be refilled.

Confirm the selection by pressing "ENTER".

10. Press "REV.PROG."
11. Press "START" to start vacuum pumping.
12. Move the A/C hoses slightly and make sure that there are no leaks in the system.

The pressure must not increase more than 10 bar for 5 minutes.