To remove the snap-on coupling, first turn the knob (2) counter-clockwise to close the valve. Then remove the snap-on coupling by pressing the
spring-loaded catch (3), so that the locking sleeve (4) can be pulled up.

When the catch is pressed a hiss will be heard, as the catch also evacuates the refrigerant that is trapped in the snap-on coupling.

The connections on the low-pressure and high-pressure sides are of different sizes so that they cannot be mistaken.

Measuring Pressure With The Robinair 1032 Smart Cart

1. Check that both the valve on the blue low-pressure hose and the valve on the red high-pressure hose on the pressure gauge stand are closed.
2. Using a snap-on coupling, connect the blue low-pressure hose to the low-pressure side of the A/C system.
3. Using a snap-on coupling, connect the red high-pressure hose to the high-pressure side of the A/C system.
4. Open the valves on both snap-on couplings by screwing in the knobs.
5. Start the engine.

With the engine running at idling speed and the air temperature at 20 °C, the following pressures should be shown on the pressure gauge stand
when the compressor is running:

Low pressure side: 1.5-2.5 bar