9-5 Sedan (9600) L4-2.3L Turbo (B235) (2000)
Filament Monitor, Front Lights
Filament Monitor, Front Lights
The SID unit receives information on headlamp functionality from the filament monitor.
The SID unit sends B+ to the filament monitor via pin 23. If a headlamp bulb is faulty, the filament monitor output will be grounded.
The SID unit uses the information for a CHECK message (3 second delay). See Technical description, "Service Message". See: Service Message
Diagnostics
If a short-circuit to ground occurs in the filament monitor circuit, the CHECK message for a faulty lamp will be shown even though the lamp is OK In
the event of an open circuit, the CHECK message will not be shown even if one of the lamps is faulty.
Function Keys
Function Keys
The SID unit comes in two versions, SID 1 and SID 2.
The following function keys are used on SID 1:
Key
Description
O O
To increase/reduce clock setting, enter RDS time.
CLEAR
To clear the display message, zeroize the memory of the trip computer function and delete any service messages.
Arrow (down)
Scroll "down."
Arrow (up)
Scroll "up."
NIGHT PANEL
Activate/deactivate Night Panel function.