saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Direct Current Motor, Air Recirculation Flap, ACC|Page 9507 > < Direct Current Motor, Air Recirculation Flap, ACC|Page 9505
Page 10
background image

With the ignition off, fresh air is selected after 10 seconds.

Adjustment

With the diagnostics tool, the ACC can be adjusted to always start with the air recirculation flap in the position that was used the last time the car was
driven. The flap then goes immediately to this position and air recirculation can only be selected manually on the panel.

Diagnostics

In the event of an open circuit or short circuit, diagnostic trouble code B2410 is set and 21 is displayed instead of right-hand temperature when
calibrating.

Stepping Motor, Air Distribution Flap

Stepping Motor, Air Distribution Flap

The stepping motor has two windings. The windings are energized in a special order with short pulses. This makes the motor move in short steps, which
is how it got its name. The direction of rotation can be changed. When the motor is stationary, both the windings are energized continuously to lock the
motor. The stepping motor does not require a feed-back coupling to the control module (position sensor). By sending a known number of pulses, the
control module always knows how far the flap has moved. This is possible on condition that the control module has calibrated itself by turning the flap to
its respective end positions so that it knows the position of the flap.

Direct Current Motor, Air Recirculation Flap, ACC|Page 9507 > < Direct Current Motor, Air Recirculation Flap, ACC|Page 9505