saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Solar Sensor, HVAC|Service and Repair > < Component Locations|Page 10312
Page 2
background image

respect to the outside temperature so that the perceived temperature corresponds with the set temperature.

As soon as a difference occurs, the blended-air temperature must be increased or decreased. The control module turns the air-blending flap in question
until the required blended-air temperature is achieved.

Adjustment

Using the diagnostics tool, the ACC unit can be adjusted to include a larger or smaller proportion of the solar sensor value when calculating the cabin
temperature.

Diagnostics

In the event of an open circuit or short circuit, diagnostic trouble code B1340 is set and 03 is displayed instead of right-hand temperature when
calibrating. The latest valid value is used as a default value. When the ignition is turned on, 0 W/m2 is used.

Solar Sensor, HVAC|Service and Repair > < Component Locations|Page 10312