saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

SID Module - Rain Sensor|Page 2753 > < Rain Sensor (649)|Page 2750
Page 1
background image

Rain Sensor: Testing and Inspection
SID Module - Rain Sensor

Control Module Connection Test Values, Rain Sensor

Scope

This section contains the readings and instructions for measuring voltage levels on the SID unit.

Remember

-

Observe the conditions set for testing and use common sense when assessing the results.

-

First make sure that the control module is receiving power and that it is grounded.

-

Then check all the sensor inputs and signals from other systems.

-

Finally check the control module outputs. Remember that the test readings do not indicate whether the actuator is working.

-

If a test value is incorrect, consult the wiring diagram to trace which leads, connectors and components should be checked more thoroughly.

-

The specified test readings refer to those obtained with a calibrated Fluke 88/97.

-

The test readings show the signal's pulse ratio and pulse duration. A test instrument capable of giving pulse ratio and pulse duration readings
should be used. The sign indicates a positive trigger pulse, TRIG+.

SID Module - Rain Sensor|Page 2753 > < Rain Sensor (649)|Page 2750