saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Condenser HVAC|Service and Repair > < Component Locations|Page 9379
Page 1
background image

Condenser HVAC: Description and Operation

Condenser

The condenser cools the gaseous and hot refrigerant so that it condenses. To do this as efficiently as possible, the refrigerant passes through four loops in
the condenser. The first loop is divided into 13 passages. The second loop into 10, the third into 7 and the fourth loop consists of 5 passages. This
construction makes it possible to minimize the size of the condenser without losing capacity.

The pressure sensor is located on the right-hand condenser tank and the receiver on the left-hand tank.

The high pressure side service connection is also located on the condenser.

Radiator fans

Car with A/C are equipped with two radiator fans. They can be connected in series, giving low speed, or in parallel, which corresponds to high speed .

The radiator fan starts at low speed if the compressor is active and any one of the following is true:

-

outside temperature is above 22 degrees C.

-

car speed is below 38 km/h and A/C pressure is above 9 bar.

The radiator fan starts at high speed if the compressor is active and the A/C pressure is above 18 bar.

The radiator fans are described in group 2, Cooling system.

Condenser HVAC|Service and Repair > < Component Locations|Page 9379