13. Press "START" to start refilling the refrigerant.
14. Stop refilling by pressing "HOLD" when about 200 grams of refrigerant has been refilled.
15. Move the A/C hoses slightly and check with a leakage detector designed for R134a that the system does not leak.
16. Continue refilling by pressing "START".

"CPL" is shown on the control panel display.

17. Close the valves for the blue low-pressure hose and the red high-pressure hose on the pressure gauge stand.
18. Start the car and read the pressure once it has stabilized.

The pressure on the low-pressure side should be 1.5-2.5 bar.

19. Close the valves on the snap-on couplings on the A/C system service connections by turning the knobs counter-clockwise.
20. Remove the snap-on couplings and refit the protective plugs in the service valves.