Control module

When the control module is supplied with current, the processor in it is tripped. The processor then reads the instructions stored in the control module's
memory.

The control module is programmed to read the inputs and activate the outputs. If the control module program is faulty, the diagnostic trouble code
"Internal Control Module Fault" will be generated.

The control module must be supplied with current before the system will function. The control module is supplied with current and the processor tripped
when the control module can be contacted by the diagnostics instrument.

Outputs 
The purpose of the system is to control a number of functions by means of various actuators, such as an injector or lamp. For the system to be capable of
performing its functions, it must be possible to activate the actuators. For this reason the actuators must be connected to the control module and have a
proper power supply or ground connection.

Inputs

A condition for the control module's capability of controlling its actuators is that the system's sensors supply it with correct values.

Sensor performance can be checked with the diagnostics instrument.

Before Changing A Control Module

Before Changing A Control Module

It is our experience that the majority of control modules returned for repair or replacement under warranty are in perfect working order. In these cases,
fitting a new control module has obviously not cured the fault. Therefore, go through all the following points carefully before changing the control
module:
1. Check the latest edition of TIS2000 to see whether the problem can be solved with a control module software update (for control modules that can

be reprogrammed).

Important:  Avoid SPS programming unless it is absolutely necessary. It is extremely important to follow the instructions for SPS programming
to avoid damaging the control module.

2. Check all grounding points and the power supply to the control module.
3. Check with a diagnostic tool that all the readings are plausible (several readings can affect one function).
4. Check with the diagnostics tool that all activations function normally. (Malfunction in one output circuit can affect another output circuit).

Initial Inspection and Diagnostic Overview|Page 4033 > < Initial Inspection and Diagnostic Overview