saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

SID Module - Rain Sensor|Page 15781 > < SID Module - Rain Sensor|Page 15779
Page 1
background image

Rain Sensor: Testing and Inspection
SID Module

Test Readings, Control Module Connections

Scope

This section contains the readings and instructions for measuring voltage levels on the SID unit.

Remember:

-

Note the test conditions and use common sense when assessing the test result.

-

First check that the control module has a power supply and is grounded.

-

Then check all sensor inputs and signals from other systems.

-

Lastly, check the control module outputs. Remember, the readings do not say anything about whether or not the actuator is in working order.

-

If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which should be checked more thoroughly.

-

The specified test readings refer to those obtained with a calibrated Fluke 88/97.

-

The test readings show the signal's pulse ratio and pulse width. A test instrument with pulse ratio and pulse width measurement must be used. The
sign indicates a positive trigger pulse, TRIG+.

SID Module - Rain Sensor|Page 15781 > < SID Module - Rain Sensor|Page 15779