1. Position the delivery pipe correctly.
2. Fit the banjo bolt but do not tighten it.
3. Fit the fan cowling and tighten the screws.
4. Plug in the connectors for the radiator fans. Fit the clip securing the hose to the expansion tank.

Fit the upper banjo bolt but do not tighten it.

5. Fit the brackets on the fan cowling and tighten them.

Fit the upper and lower banjo bolts and tighten them.
Tightening torque: 22 Nm (16 ft. lbs.) 

6. Fit the bypass pipe and valve.

7. Raise the car.
8. Fit the banjo bolt on the transmission and tighten it.

Tightening torque: 22 Nm (16. ft. lbs.) 

9. Lower the car to the floor.

10. Fill with transmission fluid, Texaco Texamatic DEXRON III (7045 EU, TL1863 US), to the correct level