4. Scribe or draw a line (2) on the camshaft position actuator at that position.

5. Measure the distance between the two lines. The measurement (3) should be 14 - 15 mm (0.55 - 0.59 inch). If the measurement is far more or far

less, the camshaft position actuator needs to be replaced.