9-7X L6-4.2L (2008)
1. Install the AIR solenoid valve (4) and the gasket (5) to the engine.
Notice: Refer to Fastener Notice.
2. Install the 2 AIR solenoid valve studs (3).
Tighten the studs to 25 Nm (18 ft. lbs.).
3. Install the transmission fluid level indicator tube (2) to the AIR solenoid valve stud (3).
4. Install the nut (1) securing the transmission fluid level indicator tube (2) to the AIR solenoid valve.
Tighten the nut to 10 Nm (89 in. lbs.).
5. Connect the AIR pump air outlet pipe to the AIR solenoid valve.
6. Connect the electrical connector to the AIR solenoid valve.
7. Install the air cleaner outlet duct. Refer to Air Cleaner Resonator Outlet Duct Replacement (See: Fuel Delivery and Air Induction/Air Cleaner
Housing/Air Cleaner Fresh Air Duct/Hose/Service and Repair/Air Cleaner Resonator Outlet Duct Replacement).