saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Variable Valve Timing Actuator|Description and Operation|Page 2459 > < Technician Safety Information|Page 2452
Page 1
background image

Variable Valve Timing Actuator: Description and Operation

Cylinder Deactivation (Active Fuel Management) System Description

To provide maximum fuel economy under light load driving conditions, the engine control module (ECM) will command the cylinder deactivation
system ON to deactivate engine cylinders 1 and 7 on the left bank, and cylinders 4 and 6 on the right bank, switching to a V4 mode. The engine will
operate on 8 cylinders, or V8 mode, during engine starting, engine idling, and medium to heavy throttle applications.

When commanded ON, the ECM will determine what cylinder is firing, and begin deactivation on the next closest deactivated cylinder in firing order
sequence. The Gen IV engine has a firing order of 1-8-7-2-6-5-4-3. If cylinder number 1 is on its combustion event when cylinder deactivation is
commanded ON, the next cylinder in the firing order sequence that can be deactivated is cylinder number 7. If cylinder number 5 is on its combustion
event when cylinder deactivation is commanded ON, then the next cylinder in the firing order sequence that can be deactivated is cylinder number 4.

Cylinder deactivation is accomplished by not allowing the intake and exhaust valves to open on the selected cylinders by using special valve lifters. The
deactivation lifters contain spring loaded locking pins that connect the internal pin housing of the lifter to the outer housing. The pin housing contains the
lifter plunger and pushrod seat which interfaces with the pushrod. The outer housing contacts the camshaft lobe through a roller. During V8 mode, the
locking pins are pushed outward by spring force, locking the pin housing and outer housing together causing the lifter to function as a normal lifter.
When V4 mode is commanded ON, the locking pins are pushed inward with engine oil pressure directed from the valve lifter oil manifold (VLOM)
assembly solenoids. When the lifter pin housing is unlocked from the outer housing, the internal pin housing will remain stationary, while the outer
housing will move with the profile of the camshaft lobe, which results in the valve remaining closed. One VLOM solenoid controls both the intake and
exhaust valves for each deactivating cylinder. There are 2 distinct oil passages going to each cylinder deactivation lifter bore, one for the hydraulic
lash-adjusting feature of the lifter, and one for controlling the locking pins used for cylinder deactivation.

Although both intake and exhaust valve lifters are controlled by the same solenoid in the VLOM, the intake and exhaust valves do not become
deactivated at the same time. Cylinder deactivation is timed so that the cylinder is on an intake event. During an intake event, the intake cam lobe is
pushing the valve lifter upwards to open the intake valve against the force of the valve spring. The force exerted by the valve spring is acting on the side
of the lifter locking pins, preventing them from moving until the intake valve has closed. When the intake valve lifter reaches the base circle of the 
camshaft lobe, the valve spring force is reduced, allowing the locking pins to move, deactivating the intake valve. However, when cylinder deactivation
is commanded ON, the exhaust valve for the deactivated cylinder is in the closed position, allowing the locking pins on the valve lifter to move
immediately, and deactivate the exhaust valve.

By deactivating the exhaust valve first, this allows the capture of a burnt air/fuel charge or exhaust gas charge in the combustion chamber. The capture of
exhaust gases in the combustion chamber will contribute to a reduction in oil consumption, noise and vibration levels, and exhaust emissions when
operating in V4 mode. During the transition from V8 to V4 mode, the fuel injectors will be turned OFF on the deactivated cylinders. The ignition system
secondary voltage or spark is still present across the spark plug electrodes on the deactivated cylinders. If all enabling conditions are met and maintained
for cylinder deactivation operation, the ECM calibrations will limit cylinder deactivation to a cycle time of 10 minutes in V4 mode, and then return to V8
mode for 1 minute.

Switching between V8 and V4 mode is accomplished in less than 250 milliseconds, making the transitions seamless and transparent to the vehicle
operator. The 250 milliseconds includes the time for the ECM to sequence the transitions, the response time for the VLOM solenoids to energize, and the
time for the valve lifters to deactivate, all within 2 revolutions of the engine crankshaft.

The cylinder deactivation system consists of the following components:

*

The VLOM assembly

*

Eight special valve lifters, 2 per deactivating cylinder

*

The engine oil pressure regulator valve for cylinder deactivation operation

*

Gen IV cylinder deactivation engine block

*

The ECM

Valve Lifter Oil Manifold (VLOM) Assembly

The cylinder deactivation system uses an electro-hydraulic actuator device called the valve lifter oil manifold (VLOM) assembly. The VLOM is bolted
to the top of the engine valley, below the intake manifold assembly. The VLOM consists of 4 electrically operated Normally Closed Solenoids. Each
solenoid controls the application of engine oil pressure to the intake and exhaust valve lifters on the cylinders selected to deactivate. Engine oil pressure
is routed to the VLOM assembly from a passage on the rear of the cylinder block.

All 4 VLOM solenoids are connected in parallel to a fused ignition 1 voltage circuit, supplied by the powertrain relay. The ground or control circuit for
each solenoid is connected to the engine control module (ECM).

When all enabling conditions are met for cylinder deactivation, the ECM will ground each solenoid control circuit in firing order sequence, allowing
current to flow through the solenoid windings. With the coil windings energized, the solenoid valve opens, redirecting engine oil pressure through the
VLOM into 8 separate vertical passages in the engine lifter valley. The 8 vertical passages, 2 per cylinder, are connected to the valve lifter bores of the
cylinders to be deactivated. When vehicle-operating conditions require a return to V8 mode, the ECM will turn OFF the control circuit for the solenoids,
allowing the solenoid valves to close. With the solenoid valves closed, engine oil pressure in the control ports is exhausted through the body of the

Variable Valve Timing Actuator|Description and Operation|Page 2459 > < Technician Safety Information|Page 2452