9-7X V8-6.0L (2008)
8. Connect the compressor suction hose to the accumulator (4).
9. Install the suction hose nut.
Tighten the nut to 48 Nm (35 ft. lbs.).
10. Connect the electrical connector to the A/C low pressure switch.
11. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging (See: Service and Repair/Refrigerant Recovery and
Recharging).
12. Leak test the fitting of the component using the J 39400-A.