saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Diagnostic Aids|Page 4788 > < Diagnostic Aids|Page 4786
Page 26
background image

9. Remove the terminal position assurance (TPA) by inserting a small flat-bladed tool into the small slot in the end of the slider and pushing on the

TPA until it comes out of the connector. When the TPA exits the opposite side of the connector, gasp the TPA and pull it completely out of the
connector.

10. Push the wire side of the terminal that is being removed toward the connector and hold it in position.

11. Insert the J 38125-560 (GM P/N 15314260) into the 2 triangular cavities on each side of the terminal at the front of the connector. See the release

tool cross reference in the Reference Guide of theJ-38125 to ensure that the correct release tool is used.

12. Carefully pull the terminal out of the connector. Always remember never use force when pulling a terminal out of a connector. If the terminal is

difficult to remove, repeat the entire procedure. 

Terminal Repair Procedure

Use the appropriate terminal and follow the instructions in theJ-38125.

Terminal Replacement Procedure

Diagnostic Aids|Page 4788 > < Diagnostic Aids|Page 4786