Page 3
background image

- Current to fan motor. Regulation of fan speed possible.

- Air valves to floor and central panel vents open.

- Vacuum servos 5 and 7 operative 7 in the first stage.

- Defroster and outer panel vents closed but leakage past valves.

- Air valves 6, 8 and 9 open (8 and 9 partially open).

Position - Floor

- Current to fan motor. Regulation of fan speed possible.

- Air valves to floor open.

- Vacuum servo 7 operative (second stage).

- Defroster, outer and central panel vents closed, leakage of air past defroster and outer panel vent valves.

- Air valves 8 and 9 wide open

Position - Comfort