saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Differential, Manual Transaxle|Adjustments|General|Page 2988 > < Differential, Manual Transaxle|Adjustments|General|Page 2986
Page 2
background image

3.  If the pinion is correctly set, the dial indicator reading in hundredths of a millimeter (+ or -) should be as stamped on the pinion. The permissible

tolerance is +/- 0.05 mm (0.002 in).