Radiator Cooling Fan Temperature Sensor / Switch > < 45/38 Degree
Page 1
background image

Coolant Temperature Sensor/Switch (For Computer): Description and Operation
25/18 Degree

Non-Turbo

Fig. 28 Thermostatic Switch

    The thermostatic switch, Fig. 28, is closed at temperatures below 77°F (25°C).  If the temperature has been higher than this, the switch will not close
until the temperature has fallen to 66°F (19°C).
    The switch is connected in parallel with terminal 12 in the ECU via terminal X1 in the decel relay.  At temperatures below 77°F (25°C), terminal 12 in
the ECU is grounded and a pulse ratio of 60° is selected.  At temperatures above 77°F (25°C), the thermostatic switch is open and the preset pulse ratio
is not selected.

Turbo

Fig. 29 Thermostatic Switches

    The thermostatic switch, Fig. 29, is closed at temperatures below 77°F (25°C).  If the temperature has been higher than this, the switch will not close
until the temperature has fallen to 66°F (19°C).
    The switch is connected in parallel with terminal 12 in the ECU.  At temperatures below 77°F (25°C), terminal 12 in the ECU is grounded and a fixed
pulse ratio of 60° is selected.  At temperatures above 77°F (25°C), the thermostatic switch is open and the preset pulse ratio is not selected.