SUBJECT:
CHECKING B+ TERMINAL CONNECTION AT PDI OR NEXT SERVICE, M84 900
ISSUE:
05/84-683
FILE IN S.I. MANUAL:
VOLUME:
I
SECTION:
3
PAGE:
78
Reduced alternator output may be experienced if the B+ connection at the alternator (heavy gray wire) is not securely tightened. Beginning immediately
all M84 900 models should have this connection checked at PDI or the next time the car is in for service.
A dim glowing of the alternator charging light with the engine running may be a result of a loose B+ connection. If tightening the B+ connection does not
eliminate a glowing charging light, check that fuse no. 13 is not blown. Repeated blowing of fuse no. 13 may be due to a defective back-up light switch.
Replace the switch only if repeated blowing of fuse no. 13 occurs and no other electrical faults can be found.