900 L4-2118cc 2.1L DOHC (1992)
Hydraulic Assembly: Service and Repair
Kickdown Wire Actuating Motor
1.
Remove clip, then disconnect cable from motor lever.
2.
Unplug electrical connector.
3.
Loosen mounting screws slightly. Remove motor by sliding it up into the slotted holes in bracket and rotating it back towards firewall.
4.
Reverse procedure to install. ASR system must be calibrated, including basic kickdown cable setting. Recalibrate ASR system.