saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Draining and Filling of Refrigerant-R134a|Page 4208 > < Draining and Filling of Refrigerant-R134a|Page 4206
Page 2
background image

Draining

Robinair Smart Cart and Robinair 17234 draining station.

1. Connect the blue low-pressure hose to the low- pressure side of the compressor.

2. Connect the red high-pressure hose to the high-pressure side of the compressor.

3. Using the yellow hose, connect the pressure gauge stand's middle outlet to the draining station.

4. Open the cocks on the blue low-pressure hose and the red high-pressure hose and the cock on the yellow hose connected to the pressure gauge

stand's middle outlet.

5. Open the blue cock ("Liquid") for liquid refrigerant and the red cock ("Gas") for gaseous refrigerant on the draining station's container.

6. Start the draining station. When draining is completed, the draining station automatically switches off or the pressure gauge shows 0.

7. Close the cocks on the blue low-pressure hose, the red high-pressure hose and the yellow hose connected to the pressure gauge stand's middle

outlet.

8. Remove the yellow hose from the draining station. Draining is now completed and work on the A/C system can commence.

Draining and Filling of Refrigerant-R134a|Page 4208 > < Draining and Filling of Refrigerant-R134a|Page 4206