Schematic diagram for Robinair

Action

1. Check the operation of the A/C system as follows:

-

Conduct performance test. Refer to "Cooling Performance Test, A/C System". See: Testing and Inspection

-

Carry out leak detection procedure. Repair any system faults or damage in conjunction with conversion when the A/C system has been drained
of refrigerant.

2. Drain the A/C system of refrigerant. Note the amount of compressor oil that is drained.
3. Repair any damage to the A/C system.
4. Remove the cover over the bulkhead space.
5. Remove the expansion valve's sensitive element and heat it in hot water to max. 50 °C (122 °F).
6. Connect the blue hose from the pressure gauge set to the service nipple on the flushing station.
7. Remove the Schrader valves and Schrader openers in the A/C system and on the equipment so that a free flow is achieved during flushing.
8. Connect one end of the blue low-pressure hose to the blue low-pressure cock on the purging station's bottle.
9. Connect the other end of the blue low-pressure hose to the high-pressure side of the compressor.

10. Remove the compressor oil filler plug and fit the adapter supplied in the kit.