Outside Temperature Display: Adjustments

1

Check carefully to make sure the sensor connections (including the connection to the frame) are making good contact.

2* Adjust the instrument by turning the potentiometer with a small screwdriver, as shown in the figure.

*

The instrument and sensor are matched, so subsequent adjustment is not usually necessary.

Fluke multimeter

The temperature should be measured over a long period of time (around 20 min) with a Fluke multi meter and a Fluke 80 TK temperature probe

(see image), and preferably at a temperature of around 0°C (32°F).