Blower Motor: Testing and Inspection

FAULT DIAGNOSIS HINTS

The ventilation fan is activated when the ignition switch is turned to the Drive position.
1. Check that fuse 6 is intact and supplied with current.
2. Check the current supplied to switch 35 and main switch 149.

IMPORTANT:  Main switch 149 is located in the air distribution control. This must be activated in order for switch 35 to receive current.

Turn switch 35 to different positions and check the current supplied to motor 36.

Resistances across resistor 74

Speed 1

3.1 +/- 0.3 ohms

Speed 2

1.15 +/- 0.1 ohms

Speed 3

0.35 +/- 0.1 ohms

Check the connectors, wiring harness and ground connections.