saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Preliminary Information|Page 5507 > < Preliminary Information|Page 5505
Page 1
background image

Trip Computer: Adjustments
Adjustment

Using the Intelligent Saab Tester (ISAT), It is possible to adjust the display of a number of parameters. The ISAT reads a programmed value and
presents this. If you do not wish to adjust this, end the routine with ESC.

Make a habit of switching the ignition off and then on when verifying any action.

Important

When the ISAT is carrying out adjustment, the Electronic Display Unit (EDU) can flash and the gauges fluctuate. This is perfectly normal.

FUEL REMAINING

Using the adjustment command "FUEL REMAINING", it is possible to adjust the fuel gauge offset. This means that an increase in fuel remaining moves
the whole scale up/down comparatively in steps of 0.52 l (rounded to one decimal).

This adjustment is made when size of the deviation in the fuel gauge is the same from empty tank to full tank. When reading "TANK CONTENTS" the
same change will be read that is programmed under "FUEL REMAINING".

For example: Read "TANK CONTENTS".

Result: 52 l.
Adjusting the fuel remaining: + 5 l.
A new reading of "TANK CONTENTS" gives 57 l

Important

Use this command with careful consideration.
If the display needs to be adjusted more than ± 7 l, the fault is somewhere else.
Conduct fault diagnosis and remedy the fault.

OUTDOOR TEMPERATURE

Using the adjustment command "OUTDOOR TEMPERATURE", it is possible to adjust the display of the outside temperature on the EDU display in
steps of 0.35° C (rounded to one decimal).

The pre-programmed value is 0.0°.

Preliminary Information|Page 5507 > < Preliminary Information|Page 5505