Voltage supply
The Electronic Display Unit (EDU) control module is supplied voltage from +30 and +15. +30 gives power feed and +15 is used to start the control
module.
Voltage is fed from +30 via fuse 17 in electrical distribution box 22A to pin 1 on the control module. +15 is fed directly from the +15 distribution
terminal to pin 37 on the control module.
The control module works over the range 7.5 - 16 V.
Grounding points
The control module is grounded via pin 21 together with the speed sensor to grounding point G8.