saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Discharge Air Temperature Sensor / Switch, HVAC|Specifications|Page 4647 > < ACC Control Module, Changing|Page 4643
Page 1
background image

Discharge Air Temperature Sensor / Switch: Specifications

Discharge Air Temperature Sensor (Blended Air Temperature Sensor)

0 °C  32 °F  ....................................................................................................................................................................................  25.5 - 30.5 kOhm

10 °C  50 °F  ....................................................................................................................................................................................  16.8 - 19.7 kOhm

20 °C  68 °F  ....................................................................................................................................................................................  11.3 - 13.0 kOhm

30 °C  86 °F   ......................................................................................................................................................................................  7.8 -  8.8 kOhm

40 °C 104 °F   .....................................................................................................................................................................................  5.4 -  6.1 kOhm

50 °C 122 °F   .....................................................................................................................................................................................  3.9 -  4.3 kOhm

60 °C 140 °F   .....................................................................................................................................................................................  2.8 -  3.2 kOhm

70 °C 158 °F   .....................................................................................................................................................................................  2.1 -  2.3 kOhm

80 °C 176 °F   .....................................................................................................................................................................................  1.5 -  1.7 kOhm

90 °C 194 °F   .....................................................................................................................................................................................  1.1 -  1.3 kOhm

Discharge Air Temperature Sensor / Switch, HVAC|Specifications|Page 4647 > < ACC Control Module, Changing|Page 4643