saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1650 > < Diagram Information and Instructions|Page 1648
Page 5
background image

Checking For Short Circuit to Ground

Checking For short-circuit To Ground

1. Hold the ohmmeter leads in contact with each other and adjust the instrument until a reading of 0 Ohms is obtained.
2. Disconnect the load and the negative battery cable.
3. Connect one of the ohmmeter leads to the short-circuited cable's connection.
4. Connect the other lead to a good grounding point on the car.
5. Move the relevant wiring harness while observing the ohmmeter.

If the ohmmeter shows infinite resistance OL there is no short circuit.

Diagram Information and Instructions|Page 1650 > < Diagram Information and Instructions|Page 1648