saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 5584 > < Symptom Related Diagnostic Procedures|Page 5582
Page 18
background image

Resistance at

0° C ( 32° F)

kOhms

5,8 - 6,2

10° C ( 50° F)

kOhms

3,8 - 4,1

20° C ( 68° F)

kOhms

2,5 - 2,8

30° C ( 86° F)

kOhms

1,7 - 1,9

40° C (104° F)

kOhms

1,2 - 1,4

A/C

Fault symptom

Symptom Related Diagnostic Procedures|Page 5584 > < Symptom Related Diagnostic Procedures|Page 5582