saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 87 > < Component Locations|Page 84
Page 1
background image

Traction Control Module: Component Tests and General Diagnostics

Checking Control Module Voltage Supply and Ground

Checking The Control Module's Voltage Supply And Ground Connections

Fault Symptom

-

Alternative 1: Traction Control System (TCS) OFF lamp on, TCS inoperative

-

Alternative 2: TCS OFF lamp and TCS lamp both fail to light when the ignition is turned ON

-

Alternative 3: Malfunctions

Action

-

When a Break Out Box (BOB) is connected during trouble diagnosis, the voltage supply and ground connections should always be connected first,
as follows:
Ignition In ON Position

1

Battery positive - pin 32 less than 0.5 Volts

2

Battery positive - pin 28 less than 0.5 Volts

3

Pin 30 - Battery negative less than 0.1 Volts

4

Pin 13 - Battery negative less than 0.1 Volts

Procedures Prior to Replacement,

Component Tests and General Diagnostics|Page 87 > < Component Locations|Page 84