saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Accumulator HVAC|Locations|Page 4758 > < Accumulator HVAC|Locations|Page 4756
Page 2
background image

Important :  Both the desiccant container and the compressor oil in the R134a system absorb water from the air, which cannot then be removed. For this
reason, any connections which are open should be immediately plugged.

7

Detach the hose to the condenser using a holding tool. Plug openings.

8

Detach the pipe to the evaporator using a holding tool. Plug openings.

9

Unplug connector to pressure switch.

10

Remove the retaining screws and lift up the desiccant container.

To Install

1

Place the desiccant container in position and tighten screws.

2

Install new O-rings to the desiccant container connections. Lubricate O-rings with synthetic Vaseline, part number (16) 30 15286.

3

Do up the pipe from the evaporator using a holding tool.

Tightening torque: 21.5 Nm (15.9 lbf ft)

4

Do up the hose from the condenser using a holding tool.

Tightening torque: 21.5 Nm (15.9 lbf ft)

5

Plug in connector to pressure switch.

6

Place the compressor in position and do up the three retaining screws. Note that the bracket for the electrical connection is secured by the upper
left-hand screw.

7

Connect electrical wire to compressor.

Accumulator HVAC|Locations|Page 4758 > < Accumulator HVAC|Locations|Page 4756