Discharge Air Temperature Sensor / Switch: Specifications

Discharge Air Temperature Sensor (Blended Air Temperature Sensor)

0 °C  32 °F  ....................................................................................................................................................................................  25.5 - 30.5 kOhm

10 °C  50 °F  ....................................................................................................................................................................................  16.6 - 19.6 kOhm

20 °C  68 °F  ....................................................................................................................................................................................  11.2 - 13.0 kOhm

30 °C  86 °F   ......................................................................................................................................................................................  7.7 -  8.8 kOhm

40 °C 104 °F   .....................................................................................................................................................................................  5.4 -  6.1 kOhm