saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

High Pressure Sensor / Switch, HVAC|Specifications|Page 5226 > < Evaporator Temperature Sensor / Switch|Removal|Page 5221
Page 1
background image

High Pressure Sensor / Switch: Specifications

Stage 1:

Allows the compressor to work at temperatures

down to .............................................................................................................................................................................................  +0 °C (32 °F)

Pressure in the system at this temperature

is about ..............................................................................................................................................................................................  2 bar (29 psi)

Stage 2:

For R12 refrigerant starts the engine's electric radiator fan at a pressure

of about  ..................................................................................................................................................................................  15 bar (210 psi)

and disconnected

at  ............................................................................................................................................................................................  11 bar (155 psi)

For R134a refrigerant, the fan is started

at  .........................................................................................................................................................................................  16.5 bar (239 psi)

and disconnected

at  .........................................................................................................................................................................................  12.5 bar (181 psi)

Stage 3:

This is a safety feature which breaks the electrical circuit to the compressor if pressure exceeds:

for R12 refrigerant  .......................................................................................................................................................................  27 bar (380 psi)
and reconnected when pressure is
below ................................................................................................................................................................................................  6 bar (90 psi)

for R134a refrigerant the switch breaks
at  ..................................................................................................................................................................................................  30 bar (435 psi)

High Pressure Sensor / Switch, HVAC|Specifications|Page 5226 > < Evaporator Temperature Sensor / Switch|Removal|Page 5221