saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Evaporator Temperature Sensor / Switch > < Discharge Air Temperature Sensor / Switch, HVAC|Removal
Page 1
background image

Discharge Air Temperature Sensor / Switch: Service and Repair
Installation

1. Place the blended air temperature sensor in position.
2. Connect both the sensor leads.
3. Press the one part of the connector into the actuator motor mounting.
4. Plug in the connector and fit a cable tie around the lead and the actuator motor mounting.
5. Refit the electrical distribution box and the glove compartment (or the main instrument and the upper part of the facia).
6. Calibrate the ACC system by pressing the "AUTO" and. "VENT' buttons at the same time.

NOTE:  During calibration, all previously stored diagnostic trouble codes are erased. Before carrying out calibration, all stored diagnostic trouble
codes should be read.