Integrated Central Electronics (ICE) Control Module: Testing and Inspection
Fault Diagnosis by Symptom

Anti-Frost Thermostat

1

Plug in the Intelligent Saab Tester (ISAT) scan tool and select "READ FAULT CODES" from the menu. If any diagnostic trouble codes are
present, continue in Trouble Code Tables.

2

With the engine running, select "ACT. OTHER FUNCT" from the ISAT scan tool menu and then "AC". The compressor should now be activated.

3

If it is not, check that a power supply of about 12 V is present on one of the- anti-frost thermometer's connector contacts.
If the voltage reading is OK, continue fault diagnosis as described in "Climate Control System, ACC".

4

If the voltage reading is not OK, connect a BOB and check the wiring for continuity/shorting between the Integrated Central Electronics (ICE)
module and the anti-frost thermostat.

NOTE:  The ISAT scan tool command should still be activated.