900 S Coupe L4-1985cc 2.0L DOHC Turbo EFI (1998)
Robinair 17644 Draining Equipment And Robinair 10094 Vacuum Pump - Filling Of R134a Refrigerant From A 725 Gramme Refrigerant
Flask
1. Close the cocks on the blue low-pressure hose and red high-pressure hose on the pressure gauge stand.
2. Close the valve in the snap-on coupling on the red high-pressure hose on the high-pressure side of the A/C system by turning the knob
anticlockwise.
3. Then remove the red high-pressure hose's snap-on coupling and refit the protective plug in the connection.
4. Place the flask with refrigerant upside down and open the cock on the flask.
NOTE: The flask with refrigerant must be stood upside down as otherwise it is not possible to empty it completely.
5. Fill with 200 grammes of refrigerant by carefully opening the cock on the blue low-pressure hose on the pressure gauge stand for about 10
seconds. 200 grammes of refrigerant corresponds to a pressure of 4-5 bar.
6. Move the A/C hoses slightly and check with a leakage detector designed for R134a that there are no leaks in the system.