900 S Sedan V6-2498cc 2.5L DOHC (1995)
Grounding Points
G34P
Grounding point, control module bracket (Power) below the right-hand A pillar.
DESCRIPTION OF OPERATION
Cars for certain markets are pre-wired for the installation of a mobile telephone, etc.
A special 6-pin connector (H62) for this purpose features:
^
current (+30 circuit) via fuse 23 (pin 1).
^
current (+15 circuit) via fuse 17 (pin 2).
^
adjustment of the lighting from rheostat 16 (pin 3).
^
reduction of radio volume during incoming/outgoing calls (pin 5).
^
ground connection (pin 4).
IMPORTANT: If a mobile telephone is installed, the current from the +15 circuit must not be used as the power supply but only for actuating a
relay.
FAULTS DIAGNOSIS HINTS
1. Check that fuse 23 is intact and supplied with current.
2. Check that current is present on pin 1 of the 6pin connector.
3. Check that fuse 17 is intact and supplied with current.
4. Check that current is present on pin 2 of the 6-pin connector.
5. Check the connectors, wiring harness and ground connections.