saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Adjustment of Functions|Page 11646 > < Adjustment of Functions|Page 11644
Page 1
background image

Maintenance Required Lamp/Indicator: Adjustments
Programming

Starting with M 1995, the Intelligent Saab Tester (ISAT) Scan Tool is equipped for programming Saab Information Display (SID) 213 and SID 4 (SID 1
with audio display). Only one basic programming routine is provided and since the ISAT Scan Tool does not show how the instrument is programmed,
the routine cannot therefore be used to check this. Basic setting of the following features is carried out and they must be adapted to the relevant market
by means of the adjustment commands.

-

Service indicator
The normal service interval is 20,000 km. This can be programmed and changed with "SERVICE INDICATOR" in the ADJUSTMENT" menu.

-

Language
The basic setting (English) can be changed with "LANGUAGE" in the "ADJUSTMENT" menu.

-

Units
The basic setting (metric) can be changed by means of the SID unit's pushbuttons.

-

Speed warning ME
This speed warning feature is inactive in the basic setting. It is activated by "SPEED WARNING ME" in the "ADJUSTMENT" menu.

NOTE:  It is advisable before programming is started to make a note of the current equipment of the SID version (Sensonic, TSAS or 
standard). These details are required in connection with programming.

SCAN TOOL DISPLAY 1

SAAB INFO DISPLAY 

ADJUSTMENT 

=>PROGRAMMING

READ SYSTEM INFO

1

Select PROGRAMMING in the ISAT Scan Tool's SAAB INFO DISPLAY program.

SCAN TOOL DISPLAY 2

PROGRAMMING OF A
NEW SID UNIT
F1 = CONTINUE
ESC = END

2

Continue to the programming phase or terminate.

SCAN TOOL DISPLAY 3

SELECT TYPE OF 
SID UNIT

SID 2/3

SELECT

3

State the SID type in question, which may be SID 2/3 or SID 4. (SID 4 = SID 1 with audio display)

SCAN TOOL DISPLAY 4

SELECT EQUIPMENT

XXX

SELECT

4 State equipment, which may be ACS (Sensonic), HOOD (TSAS), ACS/HOOD or NORMAL

SCAN TOOL DISPLAY 5

PROGRAMMING WILL 

NOW OCCUR!!

F1 = OK
ESC = END

5

Program the instrument with the entered details.

Adjustment of Functions|Page 11646 > < Adjustment of Functions|Page 11644