For instance, in the case of solenoid 1-2/3-4 (S1) (pin 1), solenoid 2-3 (S2) (pin 3) and solenoid lock-up (SL) (pin 19) about 0.7-1.5 V is lost
internally in the control module.

-

Readings taken across these pins and ground (pin 35) will then show current battery voltage less 0.7-1.5 V, which is indicated in the tables
shown.

-

A test reading of 0 V is to be regarded as a voltage level and not an absolute value.
-

Where the DRIVE signal (pin 11) is concerned, in the worst case, about 0.5-1.5 V will be lost internally in the control module.

-

A reading taken across the relevant control module pin and ground (pin 35) will then show less than 1.5 V, which is indicated in the table
shown.

-

Test readings should always be used with discrimination. All test readings are approximate.

-

Test readings %(+) and ms(+) indicate the signal's pulse ratio and pulse duration.
-

A test instrument capable of measuring pulse ratio and pulse width must be used. The sign denotes a positive trigger pulse, TRIG+.

-

All test readings are in respect of a warmed-up engine/transmission.

-

The specified test readings refer to those obtained with a calibrated Fluke 88/97, or equivalent test meter.