saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Convertible Top Electronic Control Module (ECM)|Page 10913 > < Convertible Top Electronic Control Module (ECM)|Page 10911
Page 4
background image

Push roof switch so top goes up and fabric edge of 5th bow and trunk lid edge are 30cm apart. See Figure.

Read and record value using ISAT

This value equals the 5TH BOW MOTOR OVERLAP LOW LIMIT.  [      ] (bold box)
CALCULATE 5TH BOW MOTOR OVERLAP HIGH LIMIT: 
5th Bow Motor Overlap Low Limit recorded above plus 6. 
This value equals the 5TH BOW MOTOR OVERLAP HIGH LIMIT. [      ] (bold box)

Transfer the four (4) OVERLAP values from this page to the chart at the end of this bulletin.

14.

Using the PROGRAMMING menu on ISAT, PROGRAM the values you have previously calculated using the chart.

NOTE

IF THE NUMBERS FOR A NEW PROGRAM ARE SIGNIFICANTLY LOWER THAN THE NUMBERS FOR THE EXISTING
PROGRAM, ISAT MAY NOT ACCEPT THE NEW OVERLAP HIGH LIMIT. IF ISAT REFUSES TO TAKE THE NEW VALUE, PRESS
THE FUNCTION BUTTON UNDER "OK" TO ACCEPT THE ORIGINAL VALUE. THIS WILL ALLOW YOU TO MOVE ON AND
ENTER THE NEW OVERLAP LOW LIMIT AND LOW LIMIT VALUES. RE-ENTER THE PROGRAM MENU. YOU WILL NOW BE
ABLE TO PROGRAM THE NEW HIGH OVERLAP LIMIT.

15.

Exit from the TSAS system using the END command. Cycle the ignition "OFF" and then back "ON" again. Contact TSAS again, call up the
PROGRAMMING menu, and verify that all programming has been properly performed. If any of the values differ from the values you entered in
the previous step, change the programming value again, and be sure to use the END function of the TSAS main menu.

16.

Operate the top through a complete down and up cycle. The SID should beep once at the completion of each cycle.

Warranty Information:

A warranty claim may be submitted for programming the convertible top as per this PSI using the information listed below:

Failure Code: 81107-01-0-01/06-05.
Labor Operation No.: 81107 for 0.5 hr.

A warranty claim may be submitted for adjusting the 1st bow for microswitch clearance using the information listed below:

Failure Code: 81182-01-0-01/06-05.
Labor Operation No.: 81182 for 0.3 hr.

The following information must be added to your DCS Tables:

Failed part code: 81107 - ECU Convertible
Operation Number: 81107 - Program Top
M94 -900 only 0.5
Engine type = 9
Trans. type = B
Begin and end year = 95

Convertible Top Electronic Control Module (ECM)|Page 10913 > < Convertible Top Electronic Control Module (ECM)|Page 10911