Refit the relay/fuse box and the expansion tank. Install three cable ties (85 52 633) to the front harness.
5.
Fit the two micro relays (42 24 192):
a.
M94 - 95: positions F1 and F2 (see Figure 5).
b.
M95 1/2-: position F2; position F1, fog lamps, is already in place.
6.
Attach the ground wire to same ground point as the battery negative cable on the inner fender near the maxi fuse box.
Fitting Vacuum Pressure Switch, 4 Cylinder
1.
Lift the rubber strip on the bulkhead panel flange and hang it on the pressure switch bracket.
2.
Plug the connector into the pressure switch.
3.
Use a cable tie (79 71 864) to secure the wiring harness to the vacuum pump bracket.
4.
Use a cable tie (79 71 864) to secure the vacuum switch hose to the stabilizer bar (item 1, Figure 6).
Fitting Vacuum Pressure Switch, V6